For each TSO, distances between entry and exit points are summarised in the following table.
DISTANCE MATRICES
Exit Dom A3
Exit A4
Entry A1 Entry A2
350 450
650 450
TSO A
Exit Dom B2
Exit B3
TSO B
Entry B1
550
650
Table 42: Distance table before the merger
Then it is necessary to proceed with the CWD calculations for each TSO in the multi-TSO system, as explained in table 43.
TSO A
TSO B
Allowed Revenues
70m€
65m€
E/E-Split
Entry
Entry
50%
50%
Exit
Exit
50%
50%
Revenues
Entry
Entry
35m€
32.50m€
Exit
Exit
35m€
32.50m€
Fcap – Proportions
Entry A1
Entry B1
82%
100%
Entry A2
Exit Dom B2
18%
25%
Exit Dom A3
Exit B3
91%
75%
Exit A4 9% Calculation of capacity-weighted average distance Entry A1 377
Entry B1
625
Entry A2
Exit Dom B2
450
550
Exit Dom A3
Exit B3
368
650
Exit A4
614
Calculation of the weight of each point Entry A1
Entry B1
79%
100%
Entry A2
Exit Dom B2
21%
22%
Exit Dom A3
Exit B3
86%
78%
Exit A4
14%
Allocation of costs
Entry A1
Entry B1
28m€
32.50m€
Entry A2
Exit Dom B2
7m€
7.15m€
Exit Dom A3
Exit B3
30m€
25.35m€
Exit A4
5m€
Determination of tariffs – €/kWh/h Entry A1
Entry B1
3.07
2.71m€
Entry A2
Exit Dom B2
3.67
2.38m€
Exit Dom A3
Exit B3
3.00
2.82m€
Exit A4
5.00
Table 43: Tariff derivation before the merger
216 |
TAR NC Implementation Document – Second Edition September 2017
Made with FlippingBook Online document